Test | Temperature | Humidity | Time
(hours) | Remarks |
| Cold storage | -40°C | Normal |
300 | |
| Hot storage | +85°C | Normal |
300 | |
| Hot storage high % RH | +60°C | 90%RH |
300 | |
| Thermal shocking | +85° to –40°C |
Normal | 500 cycles | Ramp rate = 3°C.min-1
Dwell at temperature = 30 mins |
| Operating cold temp | –30°C | Normal |
24 | Drive Voltage = +80V to -80VFrequency = 1Hz |
| Operating high temp | + 70°C | Normal |
24 | Drive Voltage = +80V to -80VFrequency = 1Hz |
| Operating high temp. & high humidity | + 60°C | 90%RH |
24 | Drive Voltage = +80V to -80VFrequency = 1Hz |
| Static voltage at high temp. & high humidity | + 60°C | 90%RH |
10 cycles | Voltage Cycle = 80V 5 minutes, 0V 5
minutes |
| Vibration test on packaged devices | Normal | Normal |
6 | Vibration frequency = 10 to 500 Hz
Acceleration = 5G (or 0.7mm peak to peak amplitude) |
| Shock test on packaged devices | Normal | Normal |
N/a | Acceleration = 1000 m.s-2 (102G)Duration =
6 msecDirection = XYZ (and their opposites) three
times in each axis. |
| Drop test on packaged devices | Normal | Normal |
N/a | Height of drop = 1m Floor surface =